Remove a Drive
b.
c.
Note -
4.
If you are hot-servicing the drive, locate the drive that displays the amber Fault
LED and ensure that the blue Ready to Remove LED is lit.
5.
On the drive you want to remove, complete these tasks.
54
SPARC S7-2 Server Service Manual • March 2017
Disable the NVMe drive.
# hotplug disable /SYS/DBP/NVME0
Check that the drive's state has changed from enabled to powered.
# hotplug list -lc
Power down the NVMe drive.
# hotplug poweroff /SYS/DBP/NVME0
Check that the drive's state has changed from powered to present.
# hotplug list -lc
In this state, the blue OK to Remove LED on the NVMe drive is lit.
Do not remove the drive unless the blue OK to Remove LED is lit.