Identify Faulted Components
Response
Impact
Action
faultmgmtsp>
In this example, a fault is displayed that includes these details:
Date and time of the fault (2016-05-03/16:01:02).
■
UUID (2782ad0c-91cb-c780-9663-807f0bf806df), which is unique to each fault.
■
Message ID (SPSUN4V-8001-0J), which can be used to obtain additional fault information
■
from Knowledge Base articles.
Use the message ID to obtain more information about this type of fault.
3.
a.
Obtain the message ID from console output (SPT-8000-PX in the example
above).
b.
Go to https://support.oracle.com, and search on the message ID in the
Knowledge tab, or type the URL from the Action field into a browser.
4.
Follow the suggested actions to repair the fault.
5.
If necessary, clear the fault manually.
See
"Clear a Fault Manually" on page
Related Information
"Log In to Oracle ILOM (Service)" on page 22
■
"Identify Disabled Components" on page 25
■
"Device Paths" on page 15
■
24
SPARC S7-2 Server Service Manual • March 2017
intended.
: No automated response.
: System performance may be affected.
: Use 'fmadm faulty' to provide a more detailed view of this
event. Please refer to the associated reference document at
http://support.oracle.com/msg/SPSUN4V-8001-0J for the latest
service procedures and policies regarding this diagnosis.