Replace the Battery
Set 'timezone' to 'PEDT'
-> show -d properties /SP/clock
/SP/clock
b.
If the SP policy HOST_AUTO_POWER_ON was enabled before you replaced the
battery, then it must be re-enabled.
-> set /SP/policy HOST_AUTO_POWER_ON=enabled
c.
If the /SP/clock usentpserver property was enabled before you replaced the
battery, you must re-enable it.
-> set /SP/clock usentpserver=enabled
4.
Verify the battery.
Check the status of the system battery.
-> show /SYS/MB/BAT
Related Information
"Identify Faulted Components" on page 22
86
SPARC S7-2 Server Service Manual • March 2017
Properties:
datetime = Mon Aug 22 13:20:16 2016
timezone = EDT (EST5EDT)
uptime = 2 days, 19:56:49
usentpserver = disabled