To check the fuse:
Check the fuse on the PIO board is not blown (see
Only fuses with the required rated current, voltage, and specified type must be used. Do not
repair fuses or short circuit fuse-holders. To do so could cause a shock or fire hazard.
Check for Boot Code Error:
If the H-ADCP gives a steady "beep" when power is applied, the ">" prompt appears on the screen, and a
"X" appears when additional breaks are sent, this may indicate that the boot code has been lost. This can
happen if you abort while downloading new firmware. Try downloading the firmware again.

Troubleshooting a Built-In Test Failure

The built-in diagnostic tests check the major H-ADCP modules and signal paths. The spare boards kit may
be used to repair some failures. This kit includes:
Spare Boards including PIO board, CPU board, and DSP board. These boards are held together
with the standard M4 screw assembly and kept inside a protective anti-static bag.
A disk containing your original beam cosine matrix table
Tools for installation
The Spare Boards kit is not included with the system. You can order the kit by contacting
Teledyne RD Instruments Customer Service department (see
Instruments
See
Installing the Spare Boards Kit

When to use the Spare Boards Kit

Use this Kit whenever you have any of the following problems:
Cannot communicate to the H-ADCP and you have ensured that the serial port on the com-
puter, H-ADCP Cable, Deck Box (Mariner only), and H-ADCP RS-232 to RS-422 converter (if
applicable) are all working properly.
Your H-ADCP fails any of the following PA tests at any time:
CPU Tests:
RTC
RAM
ROM
DSP Tests:
Timing RAM
Demod RAM
Demod REG
FIFOs
System Tests:
XILINK Interrupts
Receive Loop Back Test
Fuse Replacement
and Table 4, page 48).
for instructions.
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
for fuse replacement procedures).