Hs - Bins For Directional Wave Spectrum; Ht - Time Between Wave Record Pings - Teledyne WORKHORSE Operation Manual

Horizontal h-adcp
Hide thumbs Also See for WORKHORSE:
Table of Contents

Advertisement

WorkHorse H-ADCP Operation Manual
HS – Bins for Directional Wave Spectrum
Purpose
Set the list of bins to use for directional wave spectrum data if the H-ADCP is not select-
ing bins automatically.
Format
HS n1,n2...n20(Max)
Range
n? = 1 - # of Water Profiling Bins (WN).
Default
HS1, 10, 21, 22, 23
Recommended Setting. The default setting for this command is recommended for most applications.
Description
This command sets the bins to be used for directional wave spectrum processing if auto-
matic bin selection is off. The list can contain a maximum of 20 bins. The limit of each el-
ement in the list is set by the number of current profiling bins being collected. This list is
completely separate from the Velocity Spectrum bin list, to allow the selection of different
bins for Directional Wave and Velocity Spectrum processing.
Example
If automatic bin selection is turned off (HB = 0), and the H-ADCP is collecting 50 bins of
current profiling data, the highest single element in the list n1-n20 is limited to 50.
HT – Time Between Wave Record Pings
Purpose
Set the maximum interval between each wave ping.
HT hh:mm:ss.xx
Format
hh – hours
mm – minutes
ss – seconds
xx – hundredths of seconds
Range
00:00:00.00 – 23:59:59.99
Default
HT00:00:00.50
Recommended Setting. Set using WavesMon.
Description
This command sets the maximum interval between consecutive wave pings. If the num-
ber of pings per record * the time between pings is greater than the time between wave
records, then the previous wave record will complete before starting the next one.
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
May 2015
Page 187