Fault Log Commands; Available Fault Log Commands; Fault Log Command Descriptions; Fc - Clear Fault Log - Teledyne WORKHORSE Operation Manual

Horizontal h-adcp
Hide thumbs Also See for WORKHORSE:
Table of Contents

Advertisement

WorkHorse H-ADCP Operation Manual

Fault Log Commands

The H-ADCP uses the following commands to aid in troubleshooting and testing.

Available Fault Log Commands

This section lists the most often used Fault Log commands.
>f?
Available Commands:
FC ----------------------- Clear Fault Log
FD ----------------------- Display Fault Log
FX ----------------------- Toggle the Fault Log debug flag
F? ----------------------- Display Fault Log Commands
>

Fault Log Command Descriptions

FC – Clear Fault Log
Purpose
Clears the fault log.
Format
FC
Recommended Setting. Use as needed.
Description
Use this command to clear the fault log of all previous entries.
FD – Display Fault Log
Purpose
Displays the fault log.
Format
FD
Recommended Setting. Use as needed.
Description
Displaying the fault log will list why a built-in test failed. This may aid in troubleshooting.
Example
>FD
Total Unique Faults
Overflow Count
Time of first fault:
Time of last fault:
Fault Log:
Entry #
0 Code=0a08h
Parameter = 00000000h
Tilt axis X over range.
Entry #
1 Code=0a16h
Parameter = 00000000h
Tilt Y axis ADC under range.
End of fault log.
=
2
=
0
97/11/05,11:01:57.70
97/11/05,11:01:57.70
Count=
1
Delta=
Count=
1
Delta=
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
0 Time=97/11/05,11:01:57.70
0 Time=97/11/05,11:01:57.70
May 2015
Page 153

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents