HV – Bins for Velocity Spectrum
Purpose
Set the list of bins to use for velocity spectrum data if the H-ADCP is not selecting bins
automatically.
Format
HV n1,n2...n20(Max)
Range
n? = 1 - # of Water Profiling Bins (WN).
Default
HV1, 10, 21, 22, 23
Recommended Setting. The default setting for this command is recommended for most applications.
Description
This command sets the bins to be used for velocity spectrum processing if automatic bin
selection is off. The list can contain a maximum of 20 bins. The limit of each element in
the list is set by the number of current profiling bins being collected. This list is complete
separate from the Directional Wave Spectrum bin list, to allow the selection of different
bins for Directional Wave and Velocity Spectrum processing.
Example
If automatic bin selection is turned off (HB = 0), and the H-ADCP is collecting 50 bins of
current profiling data, the highest single element in the list n1-n20 is limited to 50.