May 2015
CR – Retrieve Parameters
Purpose
Resets the H-ADCP command set to factory settings.
Format
CRn
n = 0 (User), 1 (Factory)
Range
Recommended Setting. Use as needed.
Description
The H-ADCP automatically stores the last set of commands used in RAM. The H-ADCP
will continue to be configured from RAM unless it receives a CR-command or until the
RAM loses its power.
Table 19:
Retrieve Parameters
Format
Description
CR0
Loads into RAM the command set last stored in non-volatile memory (user settings) using the CK-Command.
CR1
Loads into RAM the factory default command set stored in ROM (factory settings).
CR keeps the present baud rate and does not change it to the value stored in non-volatile
memory or ROM. This ensures the H-ADCP maintains communications with the
terminal/computer.
CS – Start Pinging (Go)
Purpose
Starts the data collection cycle (same as the Tab key).
Format
CS
Recommended Setting. Use as needed. Use SurfaceView to create the command file. The CS
command will be added to the end of the command file or sent by the software.
Description
Use CS (or the Tab key) to tell the H-ADCP to start pinging its transducers and collecting
data as programmed by the other commands. If the
ping), the H-ADCP waits until it reaches the TF time before beginning the data collection
cycle.
1. After a CS-command is sent to the H-ADCP, no changes to the commands can occur until a
<BREAK> is sent.
2. If you try to record data (CFxxxx1), and the recorder is full, the H-ADCP will not start pinging
and will return a
3. The ADCP will keep pinging after the recorder is full only if serial output is turned on
(CFxxx1x). If the serial output is off, than the ADCP will shut down when the recorder is full, on
the assumption that there is no sense in using up the battery if the data is not going anywhere.
Page 144