Figure 45. Pt7 Rssi Bandwidth Test - Teledyne WORKHORSE Operation Manual

Horizontal h-adcp
Hide thumbs Also See for WORKHORSE:
Table of Contents

Advertisement

May 2015
Criteria for failure. Any one of the following conditions will flag failure for the beam:
Nominal noise floor <20 or >60
Counts for ms 1 through 4 not rising
9th ms sample not between 70 and 100% of nominal counts
To verify a RSSI failure, re-run the PT7 test in a different location and change the orientation 180 degrees
to determine if any external interference is an issue: Even try running PT7 at a different time of day to
eliminate powerful radio transmitters.
The ADCP should be in non-moving water during this test to get valid test results.
Page 164
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Figure 45.
PT7 RSSI Bandwidth Test
WorkHorse H-ADCP Operation Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents