Sound Velocity Smart Sensor Commands

The H-ADCP uses these commands for Sound Velocity Smart Sensor (SVSS) applications.

Available Sound Velocity Smart Sensor Command

>d?
Available Commands:
DW
0 -------------------- Current ID on RS-485 Bus
DB 411 ------------------- RS-485 Port Control (Baud; N/U; N/U)
DX ----------------------- Set SVSS to RAW Mode
DY ----------------------- Set SVSS to REAL Mode
DZ ----------------------- Get Single SCAN from SVSS
DS 20081 0 ---------------- Load SpeedOfSound with SVSS Sample (BITResult)
D? ----------------------- Display SVSS Commands
>

Sound Velocity Smart Sensor Descriptions

DB - RS-485 Port Control

Purpose
Change the communication parameters of the RS-485 bus.
Format
DBxyz
Range
x = 0 to 7 Baud Rate, see
y =l to 5 Unused
z =l to 2 Unused
Default
DB411
Recommended Setting. Use as needed.
Description
This command changes the communication parameters of the RS-485 bus. Currently only
the Baud Rate is changed, but all parameters are still required.
If the DB command is not set to the same baud rate as the CB command, than the
Master/Slave triggering is not reliable. When changing the DB command, confirm the change
by immediately following the DB change with a CK command (see CK command).
The DB command is not affected by the CR command once the CK command has been sent (see
CR – Retrieve
CB - Serial Port
Parameters).