Terminals; Main Unit - Bentel Security KYO 320 Installation Manual

Expandable multifunction control panel
Hide thumbs Also See for KYO 320:
Table of Contents

Advertisement

9. Replace the frontplate.
+
Ensure that the plastic tooth 111 on the frontplate,
closes the Tamper microswitch 101 properly.

Terminals

This section describes the Main Unit and BPI device ter-
minals.
The layout of Terminal Description table is as follows:
Ø the Ter. column shows the terminal identifier;
Ø the DESCRIPTION column provides a brief descrip -
tion of each terminal;
Ø the v(V) column shows the terminal voltage (the hy -
phen "–" indicates that the voltage cannot be speci -
fied for the terminal concerned);
Ø the I(A) column shows the maximum current (in Am-
peres) that can circulate on the terminal (the hyphen
"–" indicates that the current cannot be specified for
the terminal concerned);
Ø the numbers in brackets refer to the following notes.
(1) The total current draw of Main Unit terminals [+A3],
[+N3], [+A2], [+N2], [+A1], [+N1], [+B4], [+B5], [+F],
[+F1], [+] and [RED] must not exceed 3.8A for KYO320.
(2) The current draw of BPI device [+] terminals is:
Ø Keypad = 0.05 A for MIA-D, and 0.04 for
ALISON-DVP and Alison-S(B029), 0.07A for
Alison/32LP
Ø Reader = 0.03 A
Ø Input Expander = 0.02 A
Ø Output Expander = 0.02 A
+
These values refer to the current draw of the BPI
devices with no loads.
(3) The total current draw of the Input/Output Expander
[+F] terminals should not exceed 0.4 A.
n Main Unit
Ter.
DESCRIPTION
NA3
Programmable
NC3
(changeover switch contacts)
C3
+A3 Programmable Output no.3 (posi -
tive), protected by fuse
+N3 Programmable Output no. 3 (in -
trinsic security), protected by fuse
NA2
Programmable
NC2
(changeover switch contacts)
C2
+A2 Programmable Output no. 2 (posi -
tive), protected by fuse
+N2 Programmable Output no. 2 (in -
trinsic security), protected by fuse
NA1
Programmable
NC1
(changeover switch contacts)
C1
KYO320
v(V) I(A)
Output
no.
3
13.8 3(1)
13.8 3(1)
Output
no.
2
13.8 3(1)
13.8 3(1)
Output
no.
1
Ter.
+A1 Programmable Output no. 1 (posi-
tive), protected by fuse
+N1 Programmable Output no. 1 (intrin-
sic security), protected by fuse 46
+B4 Positive power supply to peripher-
als, protected by fuse
powered by the battery during
Mains failure)
+B5 Positive power supply to peripher-
als, protected by fuse
powered by the battery during
Mains failure)
M Negative
OC1 Programmable
(Open-Collector)
OC2 Programmable
(Open-Collector)
OC3 Programmable
(Open-Collector)
AS 10 KWBalance Tamper Line
L1
Programmable Input Line
:
L8
+F Power supply to detectors (posi-
tive), protected by fuse (will be
powered by the battery during
Mains failure)
+F1 Power supply to detectors (posi-
tive), protected by fuse (will be
powered by the battery during
Mains failure)
BPI1 1° branch of the BPI bus for the
BPI peripherals:
+ = positive protected by fuse
C = Command
R = Response
– = Negative
BPI2 2nd branch of the BPI bus for the
BPI peripherals:
+ = positive protected by fuse
C = Command
R = Response
– = Negative
KEY BUS:
RED
positive protected by fuse
3
BLK
negative
YEL
Receiver 1
Receiver 2
YEL2
GRN data
- Earth Terminal
LE External telephone line terminals
LI Line-sharing devices terminals (for
3
Answerphone, telephone, fax, mo-
dem, etc.)
3
INSTALLING
DESCRIPTION
(will be
(will be
Output
no.
4
Output
no.
5
Output
no.
6
v(V) I(A)
13.8 3(1)
13.8 3(1)
13.8 3(1)
3(1)
0
0
1
0
1
0
1
13.8 3(1)
13.8 3(1)
13.8 3(1)
13.8 3(1)
13.8
0.5
(1)
0
17