Mechanical installation

WARNING
Handle the torque flange carefully. The transducer might suffer
permanent damage from mechanical shock (dropping), chemical effects
(e.g. acids, solvents) or thermal effects (hot air, steam).
Never slacken the screwed rotor joints marked with sealing varnish (the
hexagon-socket screws for the measuring body and adapter flange and
the slotted screws on the type plate).
With alternating loads, you should use a screw locking device (medium)
to glue the rotor connection-screws into the counter thread in order to
prevent slackening and loss of pre–tensioning.
T10F Torque Flanges can be fitted directly to an appropriate shaft flange. The
adapter flange enables direct mounting of a cardan shaft or corresponding
corrector elements (if necessary, via an intermediate flange). Never exceed
the permissible limits specified for bending moments or for transverse and
longitudinal forces. Due to the high torsional stiffness of the T10F torque
flange, dynamic changes on the shaft run are minimized.
CAUTION
In all cases check the effect on critical speeds and natural torsional
vibrations to avoid overloading the torque flanges due to resonance
step-up.
NOTE
For regular operation observe the mounting dimensions in all cases (see
page 46) .