Form Of The Speed Output Signal - HBM T10F KF1 Operating Manual

Torque flange
Table of Contents

Advertisement

T10F
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:szss20@163.com

7.7 Form of the speed output signal

In the factory setting there are two speed signals at the speed output
(connector 2). They are 90_ phase shifted (5 V symmetrical, RS 422
complementary signals ). You may double the number of pulses set up in
each case by setting switch S6 to the "On" position. Pin 3 outputs the direction
of rotation as a static direction of rotation signal (pin 3=+5 V, pin 7=0 V
opposite pin 8), when the shaft rotates in the direction of the arrow. When
rotation speed is 0 rpm the direction of rotation signal takes the last measured
value.
Fig. 7.8: Arrow showing direction of rotation on sensor head
Fig. 7.9: Switch for doubling pulses
B 23.T10F.90 en
SUNSTAR自动化 http://www.sensor-ic.com/ TEL: 0755-83376489 FAX:0755-83376182 E-MAIL:szss20@163.com
Switch S6
Arrow showing direction
of rotation
Doubling pulses
On
Off
S6
39