Option 2, Code Sf1/Su2 - HBM T10F KF1 Operating Manual

Torque flange
Table of Contents

Advertisement

T10F
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:szss20@163.com

5.3 Option 2, code SF1/SU2

On the stator housing there are two 7–pin device connectors (Binder 723),
and if the speed module option is used there is also an 8–pin device
connector. Their pin assignments depend on the chosen option.
The supply voltage and the calibration signal of plugs 1 and 3 are
direct-coupled via multifuses (automatically resetting fuses).
Pin assignment for plug 1:
Power supply and frequency output signal.
Connector
Binder 723
6
6
1
1
5
7
2
3
3
4
4
Top view
1)
Factory setting; RS 422 complementary signals
CAUTION
Option 2, code SF1/SU2 torque flanges are intended for use with DC
voltage supply only. They must not be connected to older HBM
amplifiers using square–wave excitation. This could lead to the
destruction of resistors on the connection board or other faults in the
amplifiers (the torque flange on the other hand is protected and when
the correct contacts have been replaced it is ready for service again).
B 23.T10F.90 en
SUNSTAR自动化 http://www.sensor-ic.com/ TEL: 0755-83376489 FAX:0755-83376182 E-MAIL:szss20@163.com
Plug
Pin assignment
Pin
1
Measuring signal torque
(frequency output; 5 V
2
Supply voltage 0 V;
3
Supply voltage 18 V ... 30 V
4
Measuring signal torque
(frequency output; 5 V
5
Measuring signal 0 V;
6
Calibration signal release 5 V...30 V
7
Calibration signal 0 V;
Shield on housing ground
Wire
colour
1)
;
/0 V)
WH
BK
BU
1)
/12 V)
RD
GY
symmetrical
GN
GY
29
Sub-D
Connector
Pin
13
5
6
12
8
14
8
HBM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T10f su2T10f sf1

Table of Contents