Order numbers, accessories

Code
Option 1: Measuring range
050Q
50 N⋅m
100Q
100 N⋅m
200Q
200 N⋅m
500Q
500 N⋅m
001R
1 kN⋅m
002R
2 kN⋅m
003R
3 kN⋅m
005R
5 kN⋅m
010R
10 kN⋅m
Code
Option 2: Electrical configuration
KF1
Output signal 10 kHz±5 kHz, excitation
voltage 14 kHz/54 V; square–wave
SF1
Output signal 10 kHz±5 kHz,
supply voltage 18...30 V DC
Output signal 10 kHz±5 kHz and ±10 V,
SU2
supply voltage 18...30 V DC
Code
Option 3: Linearity variation
including hysteresis
S
<±0.1
G
<±0.05
Order–No.:
K–T10F
Typical order:
K–T10F
Accessories, to be ordered separately:
423G–7S cable socket, 7-pole, straight cable entry,
for torque output (connector 1, 3),
423W–7S cable socket, 7-pole, 90° cable entry,
for torque output (connector 1, 3),
423G–8S cable socket, 8-pole, straight cable entry,
for speed output (connector 2),
423W–8S cable socket, 8-pole, 90° cable entry,
for speed output (connector 2),
Raw cable Kab8/00–2/2/2,
B 23.T10F.90 en
SUNSTAR自动化 http://www.sensor-ic.com/ TEL: 0755-83376489 FAX:0755-83376182 E-MAIL:szss20@163.com
1)
5 0 0 Q
S F 1
Code
Option 4: speed measuring system
0
Without rotation speed measurement system
1
360 Pulses/revolution
2
180 Pulses/revolution
3
90 Pulses/revolution
4
60 Pulses/revolution
5
30 Pulses/revolution
6
15 Pulses/revolution
3)
7
720 Pulses/revolution
Code
Option 5: Connecting cable
V0
Without connecting cable
V1
Torque connecting cable for KF1, 423–free ends, 6 m
*)
V2
Torque connecting cable for KF1, 423–free ends, max. 80 m
V3
Torque connecting cable for KF1, 423–MS3106PEMV, 6 m
*)
V4
Torque connecting cable for KF1, 423–MS3106PEMV, max. 80 m
V5
Torque connecting cable for SF1/SU2, 423–D-Sub 15P, 6 m
*)
V6
Torque connecting cable for SF1/SU2, 423–D-Sub 15P, max. 50 m
W1
One torque and speed cable each, 423–D-Sub 15P, 6 m
*)
W2
One torque and speed cable each, 423–D-Sub 15P, max. 50 m
Code
Option 6: Fitted couplings MODULFLEX
N
Without coupling
Y
With coupling
S
0
V 5
Y
order no. 3–3101.0247
order no. 3–3312.0281
order no. 3–3312.0120
order no. 3–3312.0282
order no. 4–3301.0071
2)
1)
With voltage output <±0.07
2)
With option 2, codes SF1, SU2
only
3)
With option 1, codes 002R,
003R, 005R, 010R only
4)
For specifications see data sheet
D23.T10FBSD.x
*)
*)
When selecting V2, V4,
m
V6 and W2 please state
*)
m
length of cable required.