Mechanical Installation; Important Measures For Installation; General Installation Guidelines; Mounting Accessories For Tensile Loading/Compressive Loading - HBM Z4A Mounting Instructions

Force transducer with s.g measurement system
Hide thumbs Also See for Z4A:
Table of Contents

Advertisement

12
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:szss20@163.com
5

Mechanical installation

5.1 Important measures for installation

– treat the transducer gently
– if measuring compressive forces, make sure there is a solid support
structure
– the force-introduction surfaces must be scrupulously clean and carry in full
– keep to the depths of engagement for threaded rods or knuckle eyes
– do not overload the transducer.
WARNING
If there is a risk of breakage through overload on the
transducer and thus a risk to persons, additional safety
measures are to be taken.

5.2 General installation guidelines

The measurement direction in which forces act on the transducer must be as
precise as possible.
WARNING
Torsion and bending moments, eccentric loading and
transverse forces result in measurement errors and if limit
values are exceeded, could destroy the transducer.
5.3 Mounting accessories for tensile loading/
compressive loading
Knuckle eyes are provided for Z4A installation. This mounting accessories
prevent the introduction of torsional moments and when 2 knuckle eyes are
used, stop bending moments and transverse and angular loading being
introduced in the transducers. The knuckle eyes are intended primarily for
static tensile and compressive loading of the transducer.