Setting Up The Number Of Pulses - HBM T10F KF1 Operating Manual

Torque flange
Table of Contents

Advertisement

T10F
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:szss20@163.com

7.5 Setting up the number of pulses

If the speed module option is being used, the number of pulses per revolution
of the rotor can be adjusted with the aid of DIP switches S1 to S4.
Fig. 7.6: Switches for setting up the number of pulses
Setting up the number of pulses
1. Remove the stator cover.
2. Set up the required number of pulses in accordance with Tab. 7.1 using
switches S1 to S4.
1)
Pulses/revolution
Torque
50 N⋅m...1 kN⋅m
Torque
2 kN⋅m...10 kN⋅m
Switch position for number of pulses (
Tab. 7.1:
1)
Factory setting depending on order option 4.
B 23.T10F.90 en
SUNSTAR自动化 http://www.sensor-ic.com/ TEL: 0755-83376489 FAX:0755-83376182 E-MAIL:szss20@163.com
Switches S1 to S4
360
180
S4
S1
S4
S1
90
60
30
¢ switch buttons)
37
15
720
HBM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T10f su2T10f sf1

Table of Contents