QuickLabel QL-60 User Manual page 129

Table of Contents

Advertisement

Table 45: Pin assignment of the I/O interface (Continued)
Pin
18
19
20
21
22
23
24
25
QL-30/60 User Guide
Signal
Name
RSTERR
P24_INT
P24_EXT
PEELPOS
Bit 3
ERROR
STOP
-
-
GND_EXT
Description
Reset
Error state of the printer will
be reset.
Internal operating voltage
+24 V, Si T 100mA for
external consumers e.g.
sensors, trigger switches
External operating voltage
+24 V
Label in peel-off position
For peel-off mode only.
A label is in peel-off position.
User Bit 3 is set
General error message
The operation will be stopped
and the error type will be
displayed.
Stop signal to interrupt the
operation
Do not use
Ground of the external 24 V
I/O Interface
Activation / Active
State
Switch on +24 V
between Pin 18 and
Pin 25
+24 V on Pin 21
0 V on Pin 22
Switch on +24 V
between Pin 23 and
Pin 25