Mask Table - Symmetricom TimeProvider 1100 Reference Manual

Edge clock tl1 reference guide
Hide thumbs Also See for TimeProvider 1100:
Table of Contents

Advertisement

Table 2-35. SET-TH – Keywords and Values for all <aids> (Continued)
<keyword>
<value>
FFOFF-60
100 to 10000000
(ps/s)
SLIPCHG
0 to 255
Table 2-36. Mask Table
MTIE-1
DEFAULT
10 000
GPS-R
150
PRS
10
DS1
302
OCN
600
PRC
25
TYPEI
750
TYPEII
302
Example
To set the system's operating mode to Subtending:
Input
SET-TH:::TP1000::;
Normal Response
TP-SSU 05-02-10 13:35:56
M
TP1000 COMPLD
;
Autonomous Message
TP-SSU 05-02-10 13:35:56
A
1166 REPT EVT
"GPS,EQPT:THRCHG,TC,05-02-10,13-35-56,,,,:\"PM THRESHOLD HAS CHANGED,
FFOFF-60\""
;
097-58001-01 Revision E – September 2006
Fractional Frequency Offset threshold for 60 second
calculation period, defined in ps per s
Maximum number of slips that can occur in a
24-hour period
MTIE-5
MTIE-10
50 000
100 000
150
150
10
12
312
325
1000
1000
25
25
750
1000
312
325
Chapter 2 TL1 Command Syntax and Description
Description
MTIE-50
MTIE-100
500 000
1 000 000
150
150
25
39
325
550
1000
1000
25
39
2000
2000
425
1000
TimeProvider TL1 Reference Guide 137
Set Threshold (SET-TH)
Default
10 000 000
4
MTIE-500
FFOFF-60
5 000 000
10 000 000
155
50 000
155
1000
1002
12 000
1002
370 000
155
1000
2000
2900
1000
1000

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Timeprovider 1000

Table of Contents