Device Management
5
Figure 29: Port Mirroring Form
1. Port Mirroring Box
2.
Configure the following parameter(s) as required:
Parameter
Port Mirroring
Source Port
Source Direction
Target Port
Click Apply.
3.
Section 3.6.10

Configuring Link Detection

To configure link detection, do the following:
Navigate to Ethernet Ports » Configure Link Detection. The Link Detection form appears.
1.
70
2. Source Port Box
3. Target Port Box
Description
Synopsis: { Disabled, Enabled }
Default: Disabled
Enabling port mirroring causes all frames received and transmitted by the source port(s)
to be transmitted out of the target port.
Synopsis: Any combination of numbers valid for this parameter
The port(s) being monitored.
Synopsis: Egress and Ingress, Egress Only
Default: Egress and Ingress
Specifies monitoring whether both egress and ingress traffics or only egress traffic of the
source port.
Synopsis: 1 to maximum port number
Default: 1
The port where a monitoring device should be connected.
4. Apply Button
5. Reload Button