Device Management
Parameter
Index
Variable
Rising Thr
Falling Thr
Value
Type
Interval
Startup Alarm
Rising Event
Falling Event
92
Description
Synopsis: 1 to 65535
Default: 1
The index of this RMON Alarm record.
Synopsis: SNMP Object Identifier - up to 39 characters
The SNMP object identifier (OID) of the particular variable to be sampled. Only variables
that resolve to an ASN.1 primitive type INTEGER (INTEGER, Integer32,Counter32,
Counter64, Gauge, or TimeTicks) may be sampled. A list of objects can be printed using
shell command 'rmon'. The OID format: objectName.index1.index2... where index format
depends on index object type.
Synopsis: -2147483647 to 2147483647
Default: 0
A threshold for the sampled variable. When the current sampled variable value is
greater than or equal to this threshold, and the value at the last sampling interval was
less than this threshold, a single event will be generated. A single event will also be
generated if the first sample after this record is created is greater than or equal to
this threshold and the associated startup alarm ils equal to 'rising'.After rising alarm is
generated, another such event will not be generated until the sampled value falls below
this threshold and reaches the value of FallingThreshold.
Synopsis: -2147483647 to 2147483647
Default: 0
A threshold for the sampled variable. When the current sampled variable value is
less than or equal to this threshold, and the value at the last sampling interval was
greater than this threshold, a single event will be generated. A single event will also
be generated if the first sample after this record is created is less than or equal to this
threshold and the associated startup alarm ils equal to 'falling'.After falling alarm is
generated, another such event will not be generated until the sampled value rises above
this threshold and reaches the value of RisingThreshold.
Synopsis: -2147483647 to 2147483647
The value of monitoring object during the last sampling period. The presentation of
value depends of sample type ('absolute' or 'delta').
Synopsis: { absolute, delta }
Default: delta
The method of sampling the selected variable and calculating the value to be compared
against the thresholds. The value of sample type can be 'absolute' or 'delta'.
Synopsis: 0 to 2147483647
Default: 60
The number of seconds in over which the data is sampled and compared with the rising
and falling thresholds.
Synopsis: { rising, falling, risingOrFalling }
Default: risingOrFalling
The alarm that may be sent when this record is first created if condition for raising alarm
is met. The value of startup alarm can be 'rising', 'falling' or 'risingOrFalling'.
Synopsis: 0 to 65535
Default: 0
The index of the event that is used when a falling threshold is crossed. If there is no
corresponding entryl in the Event Table, then no association exists. In particular, if this
value is zero, no associated event will be generated.
Synopsis: 0 to 65535
Default: 0