Clearing Cable Diagnostics - Siemens RUGGEDCOM ROS User Manual

Hide thumbs Also See for RUGGEDCOM ROS:
Table of Contents

Advertisement

RUGGEDCOM ROS
User Guide
10
Figure 33: Cable Diagnostics Parameters Form
1. Port Box
2. State Options
Fail /Total Box
5.
Under Runs, enter the number of consecutive diagnostic tests to perform. A value of 0 indicates the test will
run continuously until stopped by the user.
6.
Under Calib., enter the estimated Distance To Fault (DTF) value. For information about how to determine the
DTF value, refer to
7.
Select Started.
IMPORTANT!
A diagnostic test can be stopped by selecting Stopped and clicking Apply. However, if the test is
stopped in the middle of a diagnostic run, the test will run to completion.
8.
Click Apply. The state of the Ethernet port will automatically change to Stopped when the test is complete.
For information about how to monitor the test and view the results, refer to
Diagnostics
Results".
Section 3.6.11.3

Clearing Cable Diagnostics

To clear the cable diagnostic results, do the following:
1.
Navigate to Ethernet Ports » Clear Cable Diagnostics Statistics. The Clear Cable Diagnostics Statistics
form appears.
Clearing Cable Diagnostics
3. Runs Box
10. Apply Button
11. Reload Button
Section 3.6.11.4, "Determining the Estimated Distance To Fault
4. Calib. Box
5. Good Box
6. Open Box
7. Short Box
(DTF)".
Section 3.6.11.1, "Viewing Cable
Chapter 3
Device Management
1
2
3
4
5
6
7
8
9
11
8. Imped Box
9. Pass /
75