Figure 48: RMON History Controls Table
1. InsertRecord
2.
Click InsertRecord. The RMON History Controls form appears.
7
Figure 49: RMON History Controls Form
1. Index Box
2. Port Box
Button
8. Delete Button
3.
Configure the following parameter(s) as required:
Parameter
Index
Port
Requested Buckets
Granted Buckets
Adding an RMON History Control
3. Requested Buckets Box
9. Reload Button
Description
Synopsis: 1 to 65535
Default: 1
The index of this RMON History Contol record.
Synopsis: 1 to maximum port number
Default: 1
The port number as seen on the front plate silkscreen of the switch.
Synopsis: 1 to 4000
Default: 50
The maximum number of buckets requested for this RMON collection history group of
statistics. The range is 1 to 4000. The default is 50.
Synopsis: 0 to 65535
8
9
4. Granted Buckets Box
5. Interval Box
Chapter 3
Device Management
1
2
3
4
5
6
10
6. Owner Box
7. Apply