RUGGEDCOM ROS
User Guide
Section 5.8.3

Configuring LLDP for an Ethernet Port

To configure LLDP for a specific Ethernet Port, do the following:
Navigate to Network Discovery » Link Layer Discovery Protocol » Configure Port LLDP Parameters.
1.
The Port LLDP Parameters table appears.
Figure 144: Port LLDP Parameters Table
2.
Select a port. The Port LLDP Parameters form appears.
4
Figure 145: Port LLDP Parameters Form
1. Port Box
2. Admin Status List
3.
Configure the following parameter(s) as required:
Parameter
Port
Admin Status
Configuring LLDP for an Ethernet Port
3. Notifications Options
4. Apply Button
Description
Synopsis: 1 to maximum port number
Default: 1
The port number as seen on the front plate silkscreen of the switch.
Synopsis: { rxTx, txOnly, rxOnly, Disabled }
Default: rxTx
rxTx: the local LLDP agent can both transmit and receive LLDP frames through the port.
txOnly: the local LLDP agent can only transmit LLDP frames.
Setup and Configuration