User Guide
10
Figure 130: SNMP Users Form
1. Name Box
2. IP Address Box
7. Confirm Auth Key Box
NOTE
ROS requires that all user passwords meet strict guidelines to prevent the use of weak passwords.
When creating a new password, make sure it adheres to the following rules:
• Must not be less than 6 characters in length.
• Must not include the username or any 4 continuous alphanumeric characters found in the
username. For example, if the username is Subnet25, the password may not be subnet25admin
or subnetadmin. However, net25admin or Sub25admin is permitted.
• Must have at least one alphabetic character and one number. Special characters are permitted.
• Must not have more than 3 continuously incrementing or decrementing numbers. For example,
Sub123 and Sub19826 are permitted, but Sub12345 is not.
An alarm will generate if a weak password is configured. The weak password alarm can be
disabled by the user. For more information about disabling alarms, refer to
Alarms".
3.
Configure the following parameter(s) as required:
Parameter
Name
IP Address
Adding an SNMP User
3. v1/v2c Community Box
8. Priv Key Box
9. Confirm Priv Key Box
Description
Synopsis: Any 32 characters
Default: initial
The name of the user. This user name also represents the security name that maps this
user to the security group.
Synopsis: ###.###.###.### where ### ranges from 0 to 255
The IP address of the user's SNMP management station. If IP address is configured,
SNMP requests from that user will be verified by IP address as well. SNMP
Authentication trap will be generated to trap receivers if request was received from this
11
4. Auth Protocol Box