Using ROS
10.0.1.1
10.0.1.2
C:\> for /F %i in (devices) do rsh %i -l admin,admin sql select from ipAddrtable
C:\>rsh 10.0.1.1 -l admin,admin sql select from ipAddrtable
IP Address
Subnet
192.168.0.31
255.255.255.0
1 records selected
C:\>rsh 10.0.1.2 -l admin,admin sql select from ipAddrtable
0 records selected
C:\
Section 2.7

Selecting Ports in ROS

Many features in ROS can be configured for one or more ports on the device. The following describes how to
specify a single port, a range of ports, or all ports.
Select a single port by specifying the port number:
2
Select a range of ports using a dash (-) between the first port and the last port in the list:
1-4
Select multiple ports by defining a comma-separated list:
1,4,6,9
Use the All option to select all ports in the device, or, if available, use the None option to select none of the
ports.
Section 2.8

Managing the Flash File System

The following sections describe how to manage the flash file system:
Section 2.8.1, "Viewing a List of Flash Files"
Section 2.8.2, "Viewing Flash File Details"
Section 2.8.3, "Defragmenting the Flash File System"
Section 2.8.1

Viewing a List of Flash Files

To view a list of files currently stored in Flash memory, do the following:
40
IfIndex
IfStats
IfTime
1001
274409096
2218
IfName
vlan1
Selecting Ports in ROS