Adding an RMON Alarm

To add an RMON alarm, do the following:
1.
Navigate to Ethernet Stats » Configure RMON Alarms. The RMON Alarms table appears.
1
Figure 54: RMON Alarms Table
1. InsertRecord
2.
Click InsertRecord. The RMON Alarms form appears.
12
Figure 55: RMON Alarms Form
1. Index Box
2. Variable Box
Alarm List
9. Rising Event Box
3.
Configure the following parameter(s) as required:
Adding an RMON Alarm
3. Rising Thr Box
4. Falling Thr Box
10. Falling Event Box
11. Owner Box
13
5. Value Box
6. Type Options
12. Apply Button
Device Management
1
2
3
4
5
6
7
8
9
10
11
14
7. Interval Box
8. Startup
13. Delete Button
14. Reload Button