Configuring User Priviliges - Siemens RUGGEDCOM ROS User Manual

Hide thumbs Also See for RUGGEDCOM ROS:
Table of Contents

Advertisement

RUGGEDCOM ROS
User Guide
6
Figure 75: TACACS Plus Server Form
1. Server Box
Button
3.
Configure the following parameter(s) as required:
Parameter
Server
IP Address
Auth TCP Port
Auth Key
Confirm Auth Key
4.
Set the privilege levels for each user type (i.e. admin, operator and guest). For more information, refer to
Section 4.6.2.2, "Configuring User
5.
Click Apply.
Section 4.6.2.2

Configuring User Priviliges

Each TACACS+ authentication request includes a priv_lvl attribute that is used to grant access to the device. By
default, the attribute uses the following ranges:
• 15 represents the admin access level
• 2-14 represents the operator access level
Configuring User Priviliges
2. IP Address Box
3. Auth TCP Port Box
Description
Synopsis: Any 8 characters
Default: Primary
This field tells whether this configuration is for a Primary or a Backup Server.
Synopsis: ###.###.###.### where ### ranges from 0 to 255
The Server IP Address.
Synopsis: 1 to 65535
Default: 49
The IP Port on server.
Synopsis: 31 character ascii string
Default: mySecret
The authentication key to be shared with server.
Synopsis: 31 character ascii string
The authentication key to be shared with server.
Priviliges".
4. Auth Key Box
5. Confirm Key Box
Chapter 4
System Administration
1
2
3
4
5
7
6. Apply Button
7. Reload
119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents