Chapter 5
Setup and Configuration
7
Figure 140: SNMP Access Form
1. Group Box
2. Security Model Box
6. NotifyViewName Box
3.
Configure the following parameter(s) as required:
Parameter
Group
SecurityModel
SecurityLevel
ReadViewName
WriteViewName
NotifyViewName
4.
Click Apply.
192
3. Security Level Box
7. Apply Button
8. Delete Button
Description
Synopsis: Any 32 characters
The group name to which the security model and name belong. This name is used as an
index to the SNMPv3 VACM Access Table.
Synopsis: { snmpV1, snmpV2c, snmpV3 }
Default: snmpV3
In order to gain the access rights allowed by this entry, configured security model must
be in use.
Synopsis: { noAuthNoPriv, authNoPriv, authPriv }
Default: noAuthNoPriv
The minimum level of security reqwuired in order to gain the access rights allowed by
this entry. A security level of noAuthNoPriv is less than authNoPriv, which is less than
authPriv.
Synopsis: { noView, V1Mib, allOfMib }
Default: noView
This parameter identifies the MIB tree(s) to which this entry authorizes read access. If
the value is noView, then no read access is granted.
Synopsis: { noView, V1Mib, allOfMib }
Default: noView
This parameter identifies the MIB tree(s) to which this entry authorizes write access. If
the value is noView, then no write access is granted.
Synopsis: { noView, V1Mib, allOfMib }
Default: noView
This parameter identifies the MIB tree(s) to which this entry authorizes access for
notifications. If the value is noView, then no access for notifications is granted.
8
4. ReadViewName Box
5. WriteViewName Box
9. Reload Button
RUGGEDCOM ROS
User Guide
1
2
3
4
5
6
9
Adding an SNMP Group