Siemens RUGGEDCOM ROS User Manual page 134

Hide thumbs Also See for RUGGEDCOM ROS:
Table of Contents

Advertisement

Chapter 4
System Administration
• 1 represents the guest access level
To configure the privilege levels for each user type, do the following:
1.
Navigate to Administration » Configure Security Server » Configure TacPlus Server » Configure
TACPLUS Serv Privilege Config. The TACPLUS Serv Privilege Config form appears.
4
Figure 76: TACPLUS Serv Privilege Config Form
1. Server Box
2. IP Address Box
2.
Configure the following parameter(s) as required:
Parameter
Admin Priv
Oper Priv
Guest Priv
3.
Click Apply.
120
3. Auth TCP Port Box
4. Apply Button
Description
Synopsis: (0 to 15)-(0 to 15)
Default: 15
Privilege level to be assigned to the user.
Synopsis: (0 to 15)-(0 to 15)
Default: 2-14
Privilege level to be assigned to the user.
Synopsis: (0 to 15)-(0 to 15)
Default: 1
Privilege level to be assigned to the user.
5. Reload Button
Configuring User Priviliges
RUGGEDCOM ROS
User Guide
1
2
3
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents