Installing The Fan Option - HPE Apollo 2000 User Manual

Table of Contents

Advertisement

Configuration
Non-redundant
Redundant
In a redundant fan mode:
If one fan fails, the system continues to operate without redundancy. This condition is indicated
o
by a flashing amber Health LED.
If two fans fail, the system shuts down.
o
The minimum fan requirement for this server to power on is four fans (fans 1, 2, 3, and 4).

Installing the fan option

For more information about product features, specifications, options, configurations, and compatibility,
see the product QuickSpecs on the Hewlett Packard Enterprise website (http://www.hpe.com/info/qs).
To install the component:
Power down all nodes
1.
Disconnect all peripheral cables from the nodes and chassis.
2.
Remove the node from the chassis (on page 32).
3.
If installed, remove the security bezel (on page 35).
4.
Remove all drives
5.
If installed, remove the RCM module (on page 34).
6.
Remove all power supplies
7.
Remove the chassis from the rack (on page 38).
8.
Remove the access panel
9.
Install the redundant fans in the left and right fan cages.
10.
Fan
Fan
bay 1
bay 2
Fan
Fan
Fan
Fan
("Power down the
node" on page 32).
("Removing the
drive" on page 35).
("Remove the power
("Remove the chassis access
Fan bay
Fan bay
Fan
3
4
bay 5
Fan
Fan
Empty
Fan
Fan
Fan
supply" on page 34).
panel" on page 36).
Fan
Fan
bay 6
bay 7
Empty
Empty
Fan
Fan
Hardware options installation 75
Fan bay
8
Empty
Fan

Advertisement