Server in rack mode: Install the server into the rack.
•
Server in tower mode: Return the server to an upright position.
20. Connect all peripheral cables to the server.
21. Connect each power cord to the server.
22. Connect each power cord to the power source.
23. Power up the server.
24. Configure the storage controller.
The installation is complete.
Redundant fan option kit
The redundant fan option kit contains the redundant system and PCI fans. Mixed default fan + redundant fan
configuration in the same server is not supported.
Redundant fan mode is required to meet the system thermal requirements under the following conditions:
•
Server with the following options installed:
◦
SFF hot-plug SAS SSD
◦
SFF hot-plug SAS drives in box 2
•
The ambient temperature reaches 35°C (95°F) to 40°C (104°F).
Installing the redundant fans
Prerequisites
Before you perform this procedure, make sure that:
The redundant power supply is installed.
•
•
You have a T-15 Torx screwdriver available.
Procedure
1.
Power down the server.
2.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3.
Disconnect all peripheral cables from the server.
4.
Do one of the following: