Single-Slot 1U Node Right Pci Riser Cage Assembly Options - HPE Apollo 2000 User Manual

Table of Contents

Advertisement

Install the single-slot left PCI riser cage assembly and then secure it with two T-10 screws.
a.
Install the three-slot riser cage assembly and then secure it with six T-10 screws
b.
riser cage assembly
CAUTION: To prevent improper cooling and thermal damage, do not operate the node unless
all PCI riser cages or rear I/O blanks are installed, and do not operate the node unless all PCI
slots have either an expansion slot cover or an expansion board installed.
IMPORTANT: If the PCIe riser cage assembly is not seated properly, then the server does
not power up.
Install the node into the chassis
11.
Connect all peripheral cables to the nodes.
12.
Power up the node
13.

Single-slot 1U node right PCI riser cage assembly options

NOTE: If installing the Single-slot 1U right PCI riser cage assembly for Processor 2 (PN
798182-B21), a second processor is required.
NOTE: Single-slot 1U node right PCI riser cage assemblies feature different riser boards. For
more information on the riser board slot specifications, see "PCIe riser board slot definitions
(on page 26)."
To install the component:
Power down the node (on page 32).
1.
Disconnect all peripheral cables from the node.
2.
Remove the node from the chassis (on page 32).
3.
Place the node on a flat, level surface.
4.
If installed, remove the single-slot left PCI riser cage assembly
5.
assembly" on page 48).
Remove the rear I/O blanks
6.
options" on page 93).
("Installing a node into the
("Power up the
nodes" on page 32).
("Remove the rear I/O
chassis" on page 60).
("Single-slot left PCI riser cage
blank" on page 39).
Hardware options installation 86
("Three-slot

Advertisement

Table of Contents
loading

Table of Contents