Dedicated Ilo Management Port Module Option - HPE Apollo 2000 User Manual

Table of Contents

Advertisement

Finish the installation by completely tightening the screws in the same sequence.
c.
Install the air baffle (on page 42).
15.
Install any removed PCI riser cage assemblies
16.
Install the node into the chassis
17.
Connect all peripheral cables to the nodes.
18.
Power up the node
19.

Dedicated iLO management port module option

Observe the following rules and limitations when installing an dedicated iLO management port module:
If a dedicated iLO management port module is installed in a node, the node can only connect to a
network through the dedicated iLO management port module.
If a dedicated iLO management port module is installed in a node, the node cannot be accessed
through the RCM module (on page 70).
If using the RCM module iLO ports or the dedicated iLO management port module to connect to a
network, the network must operate at a speed of 1 Gb/s. The server cannot connect to the network if
the network is operating at a speed of 10/100 Mb/s or 10 Gb/s.
For more information about product features, specifications, options, configurations, and compatibility,
see the product QuickSpecs on the Hewlett Packard Enterprise website (http://www.hpe.com/info/qs).
To install the component:
Power down the node (on page 32).
1.
Disconnect all peripheral cables from the node.
2.
Remove the node from the chassis (on page 32).
3.
Place the node on a flat, level surface.
4.
Remove any installed PCI riser cage assemblies
5.
48).
Remove all rear I/O blanks
6.
Remove the knockout.
7.
Insert a flat screwdriver into the knockout.
a.
("Installing a node into the
("Power up the
nodes" on page 32).
("Remove the rear I/O
("PCI riser cage assembly
chassis" on page 60).
("Remove the PCI riser cage
blank" on page 39).
Hardware options installation 130
options" on page 84).
assembly" on page