Alarm; Event - KTI Networks KGS-1064-HP User Manual

Web management interface
Hide thumbs Also See for KGS-1064-HP:
Table of Contents

Advertisement

Jabb.
Coll.
Utilization

3.4.4.3 Alarm

Status
ID
Interval
Variable
Sample Type
Value
Startup Alarm
Rising Threshold
Rising Index
Falling Threshold
Falling Index

3.4.4.4 Event

Status
Event Index
The number of frames which size is larger than 64 octets received with invalid CRC.
The best estimate of the total number of collisions on this Ethernet segment.
The best estimate of the mean physical layer network utilization on this interface
during this sampling interval, in hundredths of a percent.
Description
Indicates the index of Alarm control entry.
Indicates the interval in seconds for sampling and comparing the rising and falling
threshold.
Indicates the particular variable to be sampled
The method of sampling the selected variable and calculating the value to be
compared against the thresholds.
The value of the statistic during the last sampling period.
The alarm that may be sent when this entry is first set to valid.
Rising threshold value.
Rising event index.
Falling threshold value.
Falling event index.
Description
Indicates the index of the event entry.
-180-

Hide quick links:

Advertisement

Table of Contents
loading