Figure 4-21 shows that six load coils were detected, with 3029 feet to the first.
From this result screen, you can do the following:
a) Press A (
) to view a frequency sweep graph of the test
Load Coil Graph
results, like that shown in Figure 4-22:
acy34s.eps
Figure 4-22. Load Coil Graph: 6 Loads
Each negative dip followed by a positive peak represents a single load coil.
The pair depicted in Figure 4-22 has six sets of these dip-and-peak
combinations, revealing the detected six loads. The farthest load is represented
on the extreme right side of the waveform, and will always have a relatively
smaller dip and peak.