2.
Verify that the pair is actually split with another pair, and then locate the
second split pair with a tracing tone probe or other standard method.
3.
As prompted, connect the CopperPro Pair 1 and 2 test leads to the two
split pairs exactly as shown in the connection diagram (Figure 4-10).
4.
Press K.
The two split pairs must be the same lengths (within ±5 %) for the
CopperPro to obtain a meaningful measurement. If not, the
CopperPro detects the imbalance and displays an error message.
The CopperPro makes the required measurements, as shown in
Figure 4-11:
5.
Press A(
Contin. Opens
which includes the selected leg length or capacitance.
6.
Press B(
TDR)
POTS Testing and Fault Location
Figure 4-11. Splits Test Result Screen
) to view continuous two-terminal information,
to obtain a more accurate value of the distance to the split.
The POTS Toolbox
Note
4
acy96s.eps