Saved Test Results
7
Saving Test Results
If you do not supply the information in the aforementioned list, the header
contains a Date/Time stamp only. Operator Name, Location, and Job Number
can optionally be added to the header.
If a group of results shares the same header information (that is, Wire Center
name, Facility Cable Number, and Pair/Terminal Number), one header appears
immediately before the first saved result in the group and is not repeated for
each subsequent result. This convention is used to conserve memory.
However, any time you modify the information that is used for the header, the
change is reflected in a new header that appears immediately before the group
of results it pertains to.
If the elapsed time between tests is greater than ten minutes, the tester places a
timestamp before the next test result. If the elapsed time between a group of
tests is less than ten minutes, a timestamp is not posted before each result.
Again, the purpose of this convention is to conserve memory.
Test results with the same Wire Center name are listed in the order in which
the tests were conducted and under the name of the specific test. This grouping
of results under a common Wire Center name allows results for multiple tests
on the same pair to be easily identified.