Setting Up A Wb Loss Test; Running A Wb Loss Test - Test Equipment Depot 990DSL User Manual

Copperpro loop tester
Table of Contents

Advertisement

Unlike the DSL Auto-Test, the WB Loss test is manually controlled. There is
no communication between the two units.

Setting Up a WB Loss Test

The WB Loss test has no test-specific setups.

Running a WB Loss Test

To run a WB Loss test, do the following:
1.
From the XDSL toolbox, select
The
WB Loss
2.
Connect the CopperPro and Sending Unit to the test pair as shown, and
press K.
3.
The CopperPro measures all signals in the 10 kHz to 1200 kHz spectrum,
and positions the cursor on the largest signal as shown in Figure 5-12.
XDSL Testing and Loop Qualification
connection diagram is displayed.
Figure 5-12. WB Loss Test Result Screen
The XDSL Toolbox
and pressL.
WB Loss
5
acy64s.eps
5-23