Users Guide

Running a Call Waiting Caller ID Test

The Call Waiting Caller ID test enables the CopperPro to place a call on the
test line to a Quiet Termination, wait to be called from another line, then
capture and display Caller ID information sent on the line by the C.O. switch.
1.
After you have selected the Call Waiting Caller ID function and either
automatically or manually dialed a C.O. Quiet Termination (or other quiet
line) as described earlier, the CopperPro waits indefinitely (in the off-hook
condition) for an incoming call from another line.
2.
If the test line is equipped with the Call Waiting Caller ID feature, the
CopperPro detects the incoming Caller ID information (sent by the C.O.
switch), and then displays the received Phone number along with the
associated Name, Date, and Message (if included).
3.
Press A(
Timing Details
4.
Press B(
Raw Data)
If the test line was not equipped with the Call Waiting Caller ID feature, the
CopperPro continues to wait for incoming data. If the Caller ID data was
garbled, the tester displays an error message.
To hang up, press M from the Caller ID results screen.

Running a Line Monitor Function

The Monitor Line function provides a high-impedance, non-intrusive method
for monitoring the audio status of a spare or working POTS pair. It is not
technically a Dial-Up test, but is most often used on working POTS lines, and
is therefore included in this group.
1.
After selecting
2.
The CopperPro internal speaker is connected to the test line at this point,
with a "Monitor Enabled" message displayed on the screen.
3.
To stop the Monitor function, press K or M.
4-60
) to view CID signal information, as above.
to view the raw hexadecimal CID data digits.
in the POTS Toolbox, press L.