Adjusted Opens Test Screen - Test Equipment Depot 990DSL User Manual

Copperpro loop tester
Table of Contents

Advertisement

Adjusted Opens Test
A cable manufacturer's data can vary by as much as 7% among cables.
Therefore, for greater accuracy, it is strongly recommended that you first
perform an Opens test on a known good pair in the cable. This data can then be
saved as a Custom Cable Type for further use on faulted pairs in the same
cable. Alternatively, if the length of a good pair is known by another more
accurate means, you can enter that length and store the data as a Custom Cable
Type. This is called an Adjusted Opens measurement.
Figure 4-8 shows the results from a balanced pair being used to create a
Custom Cable Type for future usage on other pairs in the same cable
To run an Adjusted Opens test, do the following:
1.
Run an Opens Test on a good, balanced pair in the cable.
2.
Press A(
Adjusted Opens
A screen like the one in Figure 4-8 is displayed:
POTS Testing and Fault Location
).
Figure 4-8. Adjusted Opens Test Screen
The POTS Toolbox
4
acy19s.eps
4-17

Advertisement

Table of Contents
loading

Table of Contents