Splits Test: Connection Diagram - Test Equipment Depot 990DSL User Manual

Copperpro loop tester
Table of Contents

Advertisement

990DSL
Users Guide
The "Possible Split or Water" result is generated whenever the 3T
Capacitance Ratio (TG to TR) of a balanced pair is greater than the
average ratio for the selected Cable Type. This may be due to either a
split pair condition, enough water in the cable to alter its 3T Cap.
Ratio, or a good pair having a non-standard 3T Cap. Ratio.
If the pair is a known good pair with a non-standard 3T Cap Ratio,
you can create a Custom Cable Type with those characteristics by
pressing A(
Adjusted Opens,
tests on like pairs will result in the omission of the "Possible Split or
Water" message.
To determine the approximate location of the split, proceed as follows:
1.
On the Opens test result screen, press C(Splits).
A connection diagram is displayed, as shown in Figure 4-10:
Figure 4-10. Splits Test: Connection Diagram
4-20
Notes
then D(
Save as Custom)
. Subsequent