User view
Predefined user roles
network-admin
Parameters
repeating-number: Specifies the number of executions for on-demand diagnostic tests, in the range
of 1 to 999.
Usage guidelines
Use this command to configure the number of executions for diagnostic tests to be enabled. This
command does not survive a device reboot.
Do not specify a number smaller than the number of failed tests configured by using the diagnostic
ondemand failure command.
Examples
# Set the number of executions to 2 for all on-demand diagnostic tests.
<Sysname> diagnostic ondemand repeating 2
Related commands
diagnostic ondemand failure

diagnostic ondemand start

display diagnostic configuration
diagnostic ondemand start
Use diagnostic ondemand start to enable on-demand diagnostics.
Syntax
In standalone mode:
diagnostic ondemand start slot slot-number-list test { test-name | non-disruptive } [ para
parameters ]
In IRF mode:
diagnostic ondemand start chassis chassis-number slot slot-number-list test { test-name |
non-disruptive } [ para parameters ]
Default
All on-demand diagnostic tests need to be manually enabled.
Views
User view
Predefined user roles
network-admin
Parameters
slot slot-number-list: Specifies a space-separated list of up to seven slot number items. An item
specifies a card by its slot number or specifies a range of cards in the form of start-slot-number to
end-slot-number. The end slot number must be equal to or greater than the start slot number. (In
standalone mode.)
chassis chassis-number: Specifies an IRF member device by its member ID or specifies a PEX by
its virtual chassis number. (In IRF mode.)