Predefined user roles
network-admin
mdc-admin
Parameters
priority priority: Specifies the lowest severity level for matching log messages. The level argument
can be an integer in the range of 0 to 7, or the word all. A lower number represents higher priority
level. all represents any severity level from 0 to 7. For example, specify a severity level of 3 to match
log messages from level 3 to level 0.
msg msg: Specifies a regular expression to match the message body. The msg argument
represents a regular expression, a string of 1 to 255 characters. The log message must use the
Hewlett Packard Enterprise format. For more information about log message formats, see
"Configuring the information center."
occurs times period period: Executes the policy if the number of log matches over an interval
exceeds the limit. The times argument specifies the maximum number of log matches in the range of
1 to 32. The period argument specifies an interval in the range of 1 to 4294967295 seconds.
Usage guidelines
Use Syslog event monitor policies to monitor log messages.
EAA executes a Syslog event monitor policy when the number of matching logs over an interval
reaches the limit.
NOTE:
EAA does not count log messages generated by the RTM module when it counts log matches.
You can configure only one event for a monitor policy. If the monitor policy already contains an event,
the new event replaces the old event.
Examples
# Configure a CLI-defined policy to monitor Syslog messages for level 3 to level 0 messages that
contain the down string. Enable the policy to execute when five log matches are found within 6
seconds.
<Sysname> system-view
[Sysname] rtm cli-policy test
[Sysname-rtm-test] event syslog priority 3 msg down occurs 5 period 6

event track

Use event track to configure a track event for a CLI-defined monitor policy.
Use undo event to delete the event in a CLI-defined monitor policy.
Syntax
event track track-list state { negative | positive } [ suppress-time suppress-time ]
undo event
Default
A CLI-defined policy does not contain a track event.
Views
CLI-defined policy view