Diagnostic Monitor Interval - HPE FlexNetwork 10500 Series Network Management And Monitoring Command Reference

Hide thumbs Also See for FlexNetwork 10500 Series:
Table of Contents

Advertisement

Default
The status of monitoring diagnostics varies by test. Use the display diagnostic content command
to view the status of monitoring diagnostics for a test.
Views
System view
Predefined user roles
network-admin
Parameters
slot slot-number-list: Specifies a space-separated list of up to seven slot number items. An item
specifies a card by its slot number or specifies a range of cards in the form of start-slot-number to
end-slot-number. The end slot number must be equal to or greater than the start slot number. (In
standalone mode.)
chassis chassis-number: Specifies an IRF member device by its member ID or specifies a PEX by
its virtual chassis number. (In IRF mode.)
slot slot-number-list: Specifies a space-separated list of up to seven slot number items. An item
specifies a card or a PEX by its slot number or specifies a range of cards or PEXs in the form of
start-slot-number to end-slot-number. The end slot number must be equal to or greater than the start
slot number. (In IRF mode.)
test test-name: Specifies a test by its name, a case-sensitive character string. You can use the test ?
command to verify the value range of the test name. If you do not specify this option, the command
enables all monitoring diagnostic tests.
Usage guidelines
Monitoring diagnostics enable the system to periodically run diagnostic tests to detect hardware
faults and record test results. Monitoring diagnostics execute only non-disruptive tests.
Disruptive diagnostic tests that are being executed affect device operation or even disable certain
functions, but non-disruptive diagnostic tests do not.
The system automatically executes enabled monitoring diagnostic tests after the device starts. Use
the diagnostic monitor enable command to enable diagnostic tests that are disabled by default.
Examples
# (In standalone mode.) Enable test BoardStatusMonitor on the specified slot.
<Sysname> system-view
[Sysname] diagnostic monitor enable slot 1 test BoardStatusMonitor
Related commands

diagnostic monitor interval

diagnostic monitor interval
Use diagnostic monitor interval to configure an execution interval for monitoring diagnostic tests.
Use undo diagnostic monitor interval to restore the default.
Syntax
In standalone mode:
diagnostic monitor interval slot slot-number-list [ test test-name ] time interval
undo diagnostic monitor interval slot slot-number-list [ test test-name ]
In IRF mode: