Reset Diagnostic Result - HPE FlexNetwork 10500 Series Network Management And Monitoring Command Reference

Hide thumbs Also See for FlexNetwork 10500 Series:
Table of Contents

Advertisement

Examples
# Clear GOLD logs.
<Sysname> reset diagnostic event-log
Related commands
display diagnostic event-log

reset diagnostic result

Use reset diagnostic result to clear test results.
Syntax
In standalone mode:
reset diagnostic result [ slot slot-number [ test test-name ] ]
In IRF mode:
reset diagnostic result [ chassis chassis-number [ slot slot-number [ test test-name ] ] ]
Views
User view
Predefined user roles
network-admin
Parameters
slot slot-number: Specifies a card by its slot number. If you do not specify this option, the command
applies to all cards. (In standalone mode.)
chassis chassis-number: Specifies an IRF member device by its member ID or specifies a PEX by
its virtual chassis number. On an IRF fabric, the command applies to all member devices if you do
not specify a member device. On an eIRF system, the command applies to all IRF member devices
and PEXs if you do not specify a member device or PEX. (In IRF mode.)
slot slot-number: Specifies a card or a PEX by its slot number. On an IRF fabric, the command
applies to all cards if you do not specify a card. On an eIRF system, the command applies to all cards
and PEXs if you do not specify a card or PEX. (In IRF mode.)
test test-name: Specifies a test by its name, a case-sensitive character string. You can use the test ?
command to verify the value range of the test name. If you do not specify this option, the command
applies to all diagnostic tests.
Usage guidelines
This command does not clear the next execution time.
Examples
# (In standalone mode.) Clear test results for test BoardStatusMonitor on the specified slot.
<Sysname> reset diagnostic result slot 1 test BoardStatusMonitor
Related commands
display diagnostic result