Cooling Fan Replacement: 4A0930 And 4A1200 - YASKAWA P1000 Technical Manual

Models: 200 v class: 3/4 to 175 hp nd 400 v class: 3/4 to 1000 hp nd 600 v class: 1 to 250 hp nd
Hide thumbs Also See for P1000:
Table of Contents

Advertisement

7.4 Drive Cooling Fans
3.
Position the protective tube so the fan connector sits in the center of the protective tube. (Circuit board cooling fans
only)
4.
Guide the lead wires through the provided hooks so the wires are held in place.
5.
Double-check the relay connector to ensure that it is properly connected.
n
Installing the Cooling Fan Unit
1.
Reverse the procedure described above to reinstall the cooling fan unit.
2.
Reattach the covers and digital operator.
3.
Turn on the power supply and set o4-03 to 0 to reset the Maintenance Monitor cooling fan operation time.
u

Cooling Fan Replacement: 4A0930 and 4A1200

These models allow access to the fans from the front of the drive for fan replacement.
364
Cooling Fan B3
Relay Connector
Cooling Fan B5
Figure 7.39 Cooling Fan Wiring: 4A0515 and 4A0675
Protective tube
Circuit Board Cooling Fan B6
Relay Connector
Figure 7.40 Cooling Fan Wiring: 4A0515 and 4A0675
Figure 7.41 Install the Cooling Fan Unit: 4A0515 and 4A0675
Relay Connector
Cooling Fan B2
Cooling Fan B1
Cooling Fan B4
Circuit Board Cooling Fan B7
Relay Connector
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual

Hide quick links:

Advertisement

Table of Contents