Transformer - Henny Penny PFG-691 Technical Manual

Pressure fryer
Hide thumbs Also See for PFG-691:
Table of Contents

Advertisement

2-21. BLOWER ASSEMBLY
(Continued)

2-22. TRANSFORMER

Sept. 2004
5. Remove the flue.
6. Disconnect wires at junction box.
7. Remove the blower from the plate.
8. Replace new blower in reverse order of procedures.
The transformer reduces the voltage down to accommodate
those components with low voltage.
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the control panel.
3. Remove the 2 screws securing the transformer to the unit
and remove transformer.
4. Remove the wires from transformer.
Mark wires before removal to ensure new transformer is
wired correctly.
5. Replace with new transformer in reverse order.
2-23
Model 691