2-16. SOLENOID VALVE-
UNDER COUNTER
Aug. 2010
This is an electromechanical device that causes pressure to be
held in the frypot. The solenoid valve closes at the beginning
of the cook cycle and opens automatically at the end of the
cook cycle. If this valve should become dirty, or the Teflon
seat nicked, pressure will not build up. The gas fryer uses a
120 volt, 60 Hz coil (208/240 volt, 50 Hertz internationally).
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
Coil Check Procedure
Remove the solenoid wires from the wire nuts which are found
behind the control panel. Check across wires.
208/240 Volt, 60 Hertz
208/240 Volt, 50 Hertz
120 Volt, 60 Hertz
Replacement
1. Remove the right side panel.
2. Remove the Tru-Arc retaining clip on top of coil housing.
3. Remove the cover.
4. If only the coil is to be replaced, disconnect the two coil
wires at the wire nuts in the coil housing. Remove the coil,
insert new coil, and connect the wires at the wire nuts.
Assemble in reverse order of disassembly.
The wires may be connected in any order.
2-15
Model 691
RESULTS
150 Ohms
230 Ohms
50 Ohms