2-20. GAS CONTROL VALVE
(Continued)
Sept. 2004
4. Remove left side panel.
5. Remove control panel.
6. Unscrew nut from inlet line from the control valve.
7. Remove the bracket from behind the control valve.
8. Remove pilot light tube from control valve.
9. Loosen fittings from tee and pull control valve assembly
from the unit.
10. Remove the fittings from the defective control valve, and
place fittings on new valve.
11. Reassemble in reverse order.
2-21